EasyManua.ls Logo

Hitachi SJ Series - Page 43

Hitachi SJ Series
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-29
Chapter 4
Safety Function
e.g. Case: SS1-B then SBC-B before STO-B
[2-31]SBC-B Time linkage=03(SS1 then SBC before STO),
[2-22]SS1-B monitoring method=00(Time),
[2-12]STO-B release mode=01(With safety signal) and
[2-36]SBC-B release level =0.00%:
e.g. Case: SS1-B then SBC-B after STO-B
[2-31]SBC-B Time linkage=02( SS1 then SBC after STO),
[2-22]SS1-B monitoring method=01(frequency),
[2-12]STO-B release mode=01(With safety signal) and
[2-36]SBC-B release level =0.00%:
SBC-B
Input
Output
STO-B monitoring
Motor speed
SBC-B control
Open
Short
STO-B completed
Active
Inactive
Active
Inactive
Inactive
Active
Releasable
[2-11]STO-B Keep time
[2-33]Wait time SBC-B before STO-B
[2-35]SBC-B STO-B Release wait time
[2-34]SBC-B frequency
[2-23]SS1-B Active time
SBC-B
Input
Output
STO-B monitoring
Motor speed
SBC-B control
Open
Short
[2-34]SBC-B frequency
STO-B completed
Active
Inactive
Active
Inactive
Inactive
Active
Releasable
[2-26]SS1-B Wait time
[2-24]SS1-B Min Deceleration time
[2-25]SS1-B Max Deceleration time
[2-33]Wait time SBC-B before STO-B
[2-11]STO-B Keep time
[2-35]SBC-B STO-B Release wait time