--- 20 ---
12-6. Tightening Torque
12-7. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance and dielectric strength.
Insulation resistance: 7 MΩ or more with DC 500 V megohm tester
Dielectric strength: AC 4000 V/1 minute, with no abnormalities
....
230 V
12-8. No-load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows.
Voltage
Current (Max.)
230 V
1.3
Machine Screw (W/Washers)
Seal Lock Screw
Machine Screw
Machine Screw (for the Sensor Gear only)
Flange Nut
Tapping Screw (W/Flange)
Tapping Screw (W/Flange)
Hex. Socket Hd. Bolt
Hex. Socket Hd. Bolt
M5
M4
M4
M12
D5
D4
M5
M4
3.4 0.7 N•m (35 7 kgf•cm) (30.4 6.1 in-Ibs.)
1.8 0.4 N•m (18 4 kgf•cm) (15.6 3.5 in-Ibs.)
1.8 0.4 N•m (18 4 kgf•cm) (15.6 3.5 in-Ibs.)
1 0.2 N•m (10 2 kgf•cm) (8.7 1.7 in-Ibs.)
39.2 7.8 N•m (400 80 kgf•cm) (347.2 69.4 in-Ibs.)
2.9 0.5 N•m (30 5 kgf•cm) (26 4.3 in-Ibs.)
2.0 0.5 N•m (20 5 kgf•cm) (17.4 4.3 in-Ibs.)
5.9 1.5 N•m (60 15 kgf•cm) (52 13 in-Ibs.)
3.4 0.7 N•m (35 7 kgf•cm) (30.4 6.1 in-Ibs.)