EasyManuals Logo

Hitachi WJ200 Quick Start

Hitachi WJ200
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Quick Start Essential
Parameters
WJ200
Quick Start
b037 – Unlocks parameters (default 04)
A001 – Frequency (Speed) Source (default 02)
A002 – Run Command Source (default 02)
b012 – Motor nameplate current (default varies)
b091 – Stop Mode (default 00)
H004 – Motor nameplate poles (default 4 poles)
F001 – Keypad Speed setting (default 00.00)
F002 – Acceleration time (default 10 seconds)
F003 – Deceleration time (default 10 seconds)

Other manuals for Hitachi WJ200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi WJ200 and is the answer not in the manual?

Hitachi WJ200 Specifications

General IconGeneral
ModelWJ200
Cooling MethodFan cooled
Output Frequency0-400 Hz
Control MethodSensorless Vector Control (SVC)
Overload Capacity150% for 60 seconds
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault, Short Circuit
CommunicationRS-485 (Modbus RTU)
Braking UnitBuilt-in braking transistor (for some models)
Ambient Temperature-10 to +50°C (14 to 122°F)
EnclosureIP20
Output CurrentVaries by model
Frequency Range0.1-400Hz
Power RatingVaries by model
Storage Temperature-20 to +60°C (-4 to 140°F)
HumidityLess than 95% RH (non-condensing)
AltitudeUp to 1000m
Input Voltage200-240V AC, 380-480V AC