What causes no hydraulic functions with unchanged pump noise on Hitachi ZAXIS 35U-5N Excavators?
- LLance KeithSep 23, 2025
If there are no hydraulic functions and the hydraulic pump noise remains unchanged on your Hitachi Excavators, it could be due to a faulty pilot pump, a faulty pilot shut-off solenoid valve, a faulty wire harness (pilot shut-off solenoid valve) pilot shut-off switch, or the pilot control shut-off lever being in the LOCK position. Replace the faulty pilot pump and solenoid valve, repair or replace the wire harness, and turn the pilot shut-off lever to the UNLOCK position.