Pb (Lead Acid) Battery Program
Pb Discharge Mode:
After selecting the correct battery type, use the INC or
DEC buttons to change it to the “CHARGE“ mode.
Press the START/ENTER button and the amp rate value
will begin ashing. Use the INC or DEC buttons to adjust
the value to the desired discharge rate. The discharge
amperage can be set between 0.1 and 2.0 Amps
Press the START/ENTER button again and the voltage
rate value will begin ashing. Use the INC or DEC
buttons to set the voltage and number of cells.
Press and hold the START/ENTER button and charging will begin.
Once charging has commenced, the charger will display
the following real-time information: battery type,
charging current, battery voltage, charging time and
charged capacity.
When charging is complete, the screen will read “FINISHED” and the charger will emit
a chiming sound.
2.0A 6.0V(3P)
Pb DISCHARGE
2.0A 6.0V(3P)
Pb DISCHARGE
2.0A 6.0V(3P)
Pb DISCHARGE
Pb 1.3A 5.90V
DCH 005:33 00581
66
Other Information Displayed During the Process
Pressing the INC or DEC buttons during the charging or discharging process al-
lows you to see a variety of other information on the screen.
Input voltage from internal or external power source.
Internal and external temperatures. External Tempera-
ture requires optional temperature sensor. #44159
Cut-o temperature when using external temperature
sensor.
Safety timer ON and duration of time in minutes.
Capacity cut-o ON and set value of the capacity limit.
14.82V
IN Power Voltage
Int. Temp 37°C
Ext. Temp ----
ON 50°C
Temp Cut-Off
ON 120min
Safety Time
Capacity Cut-Off
ON 5000mAh