23
NiMH / NiCd Battery Program
This program is only suitable for charging/discharging NiCD/NiMH batteries. The
X4 AC Pro oers the following NiCD/NiMH charge modes: Charge, Auto Charge,
Discharge, Re-Peak and Cycle.
Whenever a parameter value in the program needs to be adjusted, highlight
the value by pressing the START/Enter button to make it blink; to change the
value press the DEC or INC buttons. The new value will be stored by re-pressing
the START/Enter button. If there is another parameter to be adjusted as part of a
range on the same screen, it will start blinking after the rst parameter value has
been conrmed.
BATT/PROGRAM Select
Press INC and DEC to cycle through the battery types
and press START/ENTER to select the appropriate
battery type to be charged.
NiMH / NiCd Charge Mode:
Press INC and DEC to scroll to Charge Mode. Press the
START/ENTER button to conrm.
Setting the Charge Current
Press INC and DEC to increase or decrease the charge
current. Press the START/ENTER button to conrm the
setting. The rate can be adjusted from 0.1 ~ 10A.
BEFORE YOU BEGIN CHARGING YOUR BATTERY, MAKE SURE YOU
HAVE READ AND UNDERSTAND ALL OF THE WARNINGS AND SAFETY
INFORMATION CONTAINED ON PAGES 37.
BEFORE SELECTING A CHARGE MODE, IT IS CRITICAL THAT YOU SELECT
THE CORRECT TYPE OF BATTERY TO BE CHARGED. FAILURE TO DO SO CAN
RESULT IN DAMAGE TO THE BATTERY AND POSSIBLE EXPLOSION.
Warning
NiMH BATT
BATT/PROGRAM
CURRENT 2.0A
NiMH CHARGE
CURRENT 2.0A
NIMH CHARGE
Warning
SETTING A CHARGE CURRENT THAT IS TOO HIGH CAN HAVE DAN-
GEROUS RESULTS. NEVER EXCEED THE BATTERY MANUFACTUR-
ERS RECOMMENDED CHARGE RATE