31
Item Selection Description
1 - 60
Minutes
Rest time allows the battery to cool
down between charging/discharg-
ing cycles
Default: 4mV/Cell
3 ~ 15mV/Cell
This setting is for NiMH/NiCd
batteries only. When the charger
detects that the delta peak value
you set has been reached, the
charger will indicate the battery is
fully charged.
ON / OFF
Key Beep sounds every time you
press a button. Buzzer beep or
melody sounds at various instanc-
es during operation to alert you to
certain process events.
10.0 ~ 11.0V
This setting controls the DC input
voltage. If the voltage drops below
the value you set the charging
operation will be terminated to
protect the charger.
ON / OFF
The default setting for charg-
ing Lithium batteries is to use a
balance adaptor to connect the
battery and charger in Charge, Fast
Charge, Balance Charge and Stor-
age modes. This function could be
disabled here.
O - 100
See Page 12 for a complete expla-
nation of the Power Distribution
Function
Press ENTER to load the factory
default settings
Indicates the hardware and rm-
ware versions
CHG>DCHG 10min
Rest Time
Enter
Load Factory Set
HW 1:01 SW1:00
Version
Cut-Off 11.0V
DC Input Low
Buzzer ON
Key Beep ON
100W
AC Max Power Set
ON
BAL. Connection
D.Peak Default
NiMH Sensitivity
D.Peak Default
NiCd Sensitivity