33
Memory Preset - Data Save/Load
Discharge Current: Enter the desired discharge
current.
Per Cell Discharge Voltage: Enter the desired end
per cell voltage.
Terminal Voltage (Lithium Batteries): Sets the
upper per cell charge voltage:
CHANGING THE TERMINAL VOLTAGE IS ONLY INTENDED FOR EXPERT
USERS, ANY CHANGES TO DEFAULT SETTINGS ARE COMPLETELY
AT YOUR OWN RISK. DO NOT EXCEED BATTERY MANUFACTURERS
RECOMMENDATIONS
Trickle (NiMH/NiCd): OFF or 50 ~ 300mAh Sets the
desired trickle charge voltage once the battery has
reached full charge.
Peak Delay (NiMH/NiCd): OFF or 1 ~ 5 minutes.
Sets the time between re-peak cycles
Save Program: Press the ENTER/START button
to save the program. SAVE….. will appear
momentarily while the program is written to the
memory.
Once saved the screen indicate the memory
number, battery type, cell count, charge current
and discharge current.
Recall Memory:
From the BATT/PROGRAM menu use the INC or DEC
buttons to scroll to the BATT MEMORY program and
press ENTER/START button to enter the battery
memory program . Scroll to the memory number
you wish to use then press and hold the ENTER/
START button for 3 seconds to begin the selected
process.
DSCH CURRENT
1.0A
DSCH VOLTAGE
3.0V/CELL
TVC YOUR RISK
4.20V
SAVE PROGRAM
ENTER
[ BATT MEMORY 1 ]
LiPo 7.4 (2S)
[ BATT MEMORY 1 ]
C:4.0A D:1.0
[ BATT MEMORY 1 ]
LiPo 7.4 (2S)
TRICKLE
OFF
PEAK DELAY
5 Min
BATT/PROGRAM
BATT MEMORY
Warning
LiPo BALANCE
2.5A 7.4V(2S)