BA-21426-002-EN 06.08.2010 5
EN
1. INSTALLATION
1.1. LOCATION
– Wall clearance is not required.
– Level machine by turning the feet.
– Distribute machine weight equally onto all feet.
NOTE: Vapor may escape from the dishwasher door. Therefore, adja-
cent furniture has to be protected to prevent swelling.
1.2. ELECTRICAL CONNECTION
Must be carried out by an authorized technician according to
the local and national codes.
For Australia: in accordance with AS/NZS3500.1
– The electrical supply shall comply with the name-plate data.
– Adaptation to an alternative electrical supply is achievable as per
wiring diagram. Respective schemata are adjacent to the connec-
tion terminal.
– Line fuses and cable cross section shall comply with the require-
ments.
– A cut-off device shall be provided to connect the supply cord (isolat-
ing switch or accessible plug device).
NOTE: According to EN 60 335 the appliance must be connected to
an equipotential conductor. The connecting screw (
) is lo-
cated beside the cable inlet.