6 06.08.2010 BA-21426-002-EN
EN
1.3. Water ConneCtion
Must be carried out by an authorized technician according to
the national and local codes.
The machine must be operated with potable water. For water
with an extremely high mineral content an external deminerali-
sation is strongly recommended.
Connect to warm water, if possible (max. 60°C).
For use of switchable cold water rinse, connect to cold water, if
possible (max. 20°C).
Water hardness:
Machines without softener: max. 3.75° Clark = 0.5 mmol/l.
Machines with softener: max. 37.5° Clark = 5.3 mmol/l.
Line flow pressure 0.5 – 10 bar
If the line flow pressure is above 10 bar, provide pressure
reducer at source.
Connect the union nut “A” (3/4”) of the water supply hose to the
site shut off valve.
Do not kink or cut the supply hose.
If an extended supply hose is required, use one of the same specifi-
cations as the original.
1.4. Drain ConneCtion
Connection between machine and site drain must not exceed max.
height of 0.75 m (GXH: 0.6 m).
Do not kink the drain hose.
A
max. 0.75 m
1. INSTALLATION