TROUBLESHOOTING
TROUBLESHOOTING GUIDE
Symptoms Possible Causes
Mixer will not start. • Circuit protector is in open position - check fuse or disconnect
switch.
• Mixer is overloaded.
• Wire cage is not in the closed, front-center position.
• Bowl is not in closed (locked) position.
Agitator touches bowl. • Bowl is not in closed (locked) position.
• Improper agitator clearance - refer to the Maintenance section for
adjustment procedure.
• Agitator is not installed properly.
Planetary seal squeaks. • Seal requires occasional lubrication - refer to the Maintenance
section.
Timer displays error code
(ErXX).
• If the error code is ashing - disconnect electrical power from
mixer for 1 minute, then reconnect. If symptoms still exist, contact
your local Hobart Service oce.
SERVICE
If service is needed on this equipment, contact your local Hobart Service oce @ 1-888-4HOBART.