16 08.10.2010 BA-21870-001-GB
GB
5.3. SELECT PROGRAM
! The machine runs automatically using the Standard cycle program.
If needed, it is possible to select a different program.
! To show the present program, push the Program button before
starting the wash cycle. To change the program, push the Program
button again. The theoretical runtime is then shown in the lower
display.
P01 = Short cycle
P02 = Standard cycle
P03 = Intensive cycle
P04 = Continuous cycle
H = Hygiene cycle (see section 6.4.)
An operating Continuous cycle is shown by the running lights on the
display. To stop the cycle, push the ON/OFF button
➀
(After 20 minutes
the machine will stop automatically.). After a short break, rinse starts
automatically.
The machine continues with the chosen cycle until it is switched off or
another program is chosen.
PREMAX MODELS UP/UPT:
During Intensive cycle P03, a pre-soaking phase occurs using steam and
detergent direct injection. For these models, the Intensive cycle P03 can
also be selected directly by using button
➂
. Pushing button
➂
again,
switches the machine back to the Standard cycle.
5. OPERATION