EasyManua.ls Logo

Hobart UP series - Settings and Counter Value Adjustments; Adjusting Detergent Dosage Quantity; Adjusting Rinse Aid Dosage Quantity

Hobart UP series
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BA-21870-001-GB 08.10.2010 21
GB
Attention:
The machine has to be switched off.
! Open the door.
If the door is closed, or if no button is pressed for 15 seconds, the
indicator automatically switches off and the new settings will be saved.
Therefore, the setting procedure described below can be interrupted at
any time.
9.1. ADJUSTMENT OF DETERGENT DOSAGE
QUANTITY
! Push Stop button
and Program button
simultaneously until
the upper display
shows “CH1” and
the lower display
shows e.g.
“2.50” pre-adjusted value of the detergent dosage
= 2.50 g/l.
! To adjust the detergent dosage, push the ON/OFF button
repeat-
edly, until the desired value (0.00 - 9.50 g/l) appears.
NOTE: Adjustment should be done in accordance with chemical sup-
plier’s recommendations.
PREMAX MODELS UP/UPT:
The dosage amount for the detergent direct injection cannot be changed.
9.2. ADJUSTMENT OF RINSE AID DOSAGE QUAN-
TITY
! Push Program button
again.
The upper display
shows “CH2“.
The lower display
shows E.g.:
“0.30“ = pre-adjusted value of the rinse aid dosage time
= 0.30 g/l.
! To adjust the rinse aid dosage, push the ON/OFF button
repeat-
edly, until the desired value (0.00 - 2.00 g/l) appears.
NOTE: Adjustment should be done in accordance with chemical sup-
plier’s recommendations.
9. SETTINGS AND COUNTER VALUES