9.9. CONTROL OF THE RINSE AID DOSAGE PUMP
DISPLAY CH2
! Push Program button
again.
The upper display
shows „CH2“,
The lower display
shows the respective setting:
„0“ = not activated
„1“ = activated, according to dosage setting
„2“ = activated, setting
parallel to rinse pump
„3“ = activated, setting parallel to wash pump
„4“ = activated, setting parallel to fill valve
To adjust the setting:
! Push the ON/OFF button
repeatedly until the desired setting
appears.
9.10. TERMINATION OF SETTING MODE/COUNTER
DISPLAY
! Open the door and close it again, or do not press any button for 10
seconds.