BA-21870-001-GB 08.10.2010 23
GB
9.6. ACTIVATION/DEACTIVATION OF ACOUSTIC
SIGNALS
! Close the door.
The upper display
shows “SF1”.
! Push Program button
repeatedly until “S” is shown.
! By pushing the ON/OFF button
acoustic signals can be
activated/deactivated.
The lower display
shows “I” (activated) or. “0” (deactivated).
9.7. ACTIVATION/DEACTIVATION OF CHEMICAL
SENSOR
! Push Program button
again.
The upper display
shows „CH“,
The lower display
shows the respective setting:
„0“ = sensor deactivated
„1“ = sensor activated for detergent and rinse aid
„2“ = sensor activated for detergent
„3“ = sensor activated for rinse aid
To adjust the setting:
! Push the ON/OFF button
repeatedly until the desired setting
appears.
9.8. CONTROL OF THE DETERGENT DOSAGE
PUMP
! Push Program button
again.
The upper display
shows „CH1“,
The lower display
shows the respective setting:
„0“ = not activated
„1“ = activated, according to dosage setting
„2“ = activated, setting
parallel to rinse pump
„3“ = activated, setting parallel to wash pump
„4“ = activated, setting parallel to fill valve
To adjust the setting:
! Push the ON/OFF button
repeatedly until the desired setting
appears.
9. SETTINGS AND COUNTER VALUES