8
Indicates the output of the piezo sensor R1. It must
be equal to 200 +/-30 with the shaft bare.
Press
9
Indicates the output of the piezo sensor R2. It must
be equal to 200 +/-30 with the shaft bare.
Press
10
Displays the DISTANCE sensor value
Press
11
Displays the DIAMETER sensor value
Press