EasyManua.ls Logo

Hofmann Snap-on Y2k - C8 Unbalance Threshold Suppression; C11 Setting the Orientation Mode (B9460 only)

Hofmann Snap-on Y2k
99 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Seite 83 von 99
C8 Unbalance Threshold Suppression
Displayed on selection:
Suppression threshold in grams or ounces depending on selected display mode. Factory setting is 3.5g or
equivalent.
Step 1 options:
Select the required threshold using the PLUS and MINUS keys. Press RETURN to confirm the value.
Pressing the PLUS and MINUS keys together at any stage will act like an Escape key and exit the code
without changing anything.
C11 Setting the Orientation mode (B9460 only)
Displayed on selection:
"0", "1" or "2" in display.
Step 1 options:
The PLUS or MINUS keys will alter the displayed value between zero and two. Pressing RETURN will
select the appropriate mode. The modes are;
0 No position braking after measuring run.
1 Brake to left plane if unbalance is above threshold.
2 Brake to right plane if unbalance is above threshold.
Pressing the PLUS and MINUS keys together at any stage will act like an Escape key and exit the code
without changing anything.

Table of Contents