11
Manual Operations
System Test Facility
Turn the dial to Run System Test.
There will be a one second pause
The display will show:
Use this feature to check that your valves & sprinklers are working
correctly. The unit will run all stations in sequential order. The factory
preset time of 2 minutes per station can be adjusted. The new
adjusted run time will become the new default time.
Use or to adjust and to advance.
Run A Single Station
Turn the dial to Run Single Station. There
will be a one second pause. Use to
advance to the required station and to
adjust the run time, then or .
Maximum run time is 12 hours 59 minutes.
If the water supply is from a pump system, it is critical to
ensure all outputs are connected to a valve. Any output NOT
connected to a valve, should be linked back with a wire to the
nearest output with a valve.
TIP
This prevents the pump running against a closed head.
DialEZY Controller 4 & 6 Station Instruction Manual Rev03.indd 11 10/06/2016 11:28 AM