8
Wiring
Terminal Designations
L Heat pump system monitor K Optional C-wire adaptor
C Common wire from secondary side of
cooling transformer, if 2 transformers
G Fan relay
W2
(AUX)
2nd stage heat relay (heat pump
auxiliary, emergency heat)
Y2 2nd stage compressor contactor
W
(O/B)
1st stage heat relay (changeover valve
for heat pumps)
Y 1st stage compressor contactor
U1 Terminal for indoor air quality products
(humidifier, dehumidifier, ventilator)
R Heating power. Connect to
secondary side of heating system
transformer
U2 Terminal for indoor air quality products
(humidifier, dehumidifier, ventilator)
Rc Cooling power. Connect to
secondary side of cooling
system transformer
Wiring Configurations
Two stage furnace and air-conditioning
C Common wire (optional)
W2 Heat relay (stage 2)
W Heat relay
G Fan relay
Y2 Compressor contactor (stage 2)
Y Compressor contactor (stage 1)
R Power
Notes
Thermostat C wire
is optional for this
application. C wire
required if Homekit
is used.
Set the R Jumper
Switch on the wall
plate to R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Home Round Smart Thermostat and is the answer not in the manual?

Honeywell Home Round Smart Thermostat Specifications

General IconGeneral
BrandHoneywell Home
ModelRound Smart Thermostat
CategoryThermostat
LanguageEnglish

Related product manuals