# ISU ISU Name ISU Options (factory default in bold)
221 Heat Stages / Backup Heat Stages Heat Stages: 1, 2
Backup Heat Stages: 0, 1
230 Fan Control in Heat 1 = Equipment Controls Fan
2 = Thermostat Controls Fan
253 Aux/E terminal control (Fixed to
“0” setting on all models except
TH6320U)
0 = Drive both Aux & E together
1 = Aux and E independent
255 Backup Heat Source
(Heat Pump Only)
(TH6320U / TH6220U only)
1 = Electric Forced Air
2 = Gas/Oil Forced Air (or Fossil Forced Air)
256 Emergency Heat Source (TH6320U
only)
1 = Electric Forced Air
2 = Gas/Oil Forced Air (or Fossil Forced Air)
260 External Fossil Fuel Kit
(TH6320U / TH6220U only)
0 = Thermostat Controls Backup Heat
1 = External Fossil Fuel Kit Controls Backup Heat
300 System Changeover
0 = Manual
1 = Automatic
303 Auto Changeover Differential 0 °F to 5 °F
0.0 °C to 2.5 °C
Note: Differential is NOT deadband. Resideo uses an advanced algorithm that
fixes deadband at 0 °F. The differential setting is the minimum number of degrees
from set-point needed to switch from the last mode running (heat or cool) to the
opposite mode when the thermostat is in auto-changeover. This is more advanced
than previous thermostats.
340 Backup Heat Droop
0 = Comfort
2 = 2 °F
3 = 3 °F
4 = 4 °F
5 = 5 °F
6 = 6 °F
7 = 7 °F
8 = 8 °F
9 = 9 °F
10 = 10 °F
11 = 11 °F
12 = 12 °F
13 = 13 °F
14 = 14 °F
15 = 15 °F
Note: 0 (comfort) setting only available if backup heat (ISU 255) is set to electric.
350 Upstage Timer for Backup Heat
0 = Off
1 = 30 minutes
2 = 45 minutes
3 = 60 minutes
4 = 75 minutes
5 = 90 minutes
6 = 2 hours
7 = 3 hours
8 = 4 hours
9 = 5 hours
10 = 6 hours
11 = 8 hours
12 = 10 hours
13 = 12 hours
14 = 14 hours
16 = 16 hours
355 Compressor Lockout / Balance Point
-- = Off
5 °F to 60 °F (in 5 °F increments)
15.0 °C to 15.5 °C (in 2.5 °C or 3.0 °C increments)
Note: Use a wired sensor to set compressor lockout / balance point on TH6320U
/ TH6220U.
356 Outdoor Lockout Backup Heat
-- = Off
5 °F to 65 °F (in 5 °F increments)
15.0 °C to 18.5 °C (in 2.5 °C or 3.0 °C increments)
365 Compressor Cycle Rate (Stage 1) 1 - 6
366 Compressor Cycle Rate (Stage 2) 1 - 6
370 Heating Cycle Rate (Stage 1) 1 - 12
371 Heating Cycle Rate (Stage 2) 1 - 12
375 Heating Cycle Rate Auxiliary Heat 1 - 12
378 Heating Cycle Rate Emergency Heat
(TH6320U only)
1 - 12
Advanced setup options (ISU)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Home T6 Pro Series and is the answer not in the manual?

Honeywell Home T6 Pro Series Specifications

General IconGeneral
ModelT6 Pro Series
DisplayTouchscreen
Operating ModesHeat, Cool, Auto, Off
Fan ModesAuto, On, Circulate
Warranty5-year limited warranty
Programmability7-day, 5-2 day, or non-programmable
CompatibilityWorks with most heating and cooling systems
Power SourceBattery or Hardwired (24 VAC)
ConnectivityWi-Fi
Thermostat TypeProgrammable
Display TypeLCD
StagesUp to 2 Heat / 2 Cool
Temperature Range (Heating)40°F to 90°F (4.5°C to 32°C)
Temperature Range (Cooling)50°F to 99°F (10°C to 37°C)
MountingWall
Remote AccessYes
AlertsFilter change
GeofencingYes (with Wi-Fi model)

Related product manuals