EasyManuals Logo

Honeywell 7000 User Manual

Honeywell 7000
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
HONEYWELL 7000 SOLID STATE ALARM SYSTEM
69-1192—1
12
xxxxx
xxxx
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
1
2
3
45
6
7
89
0
xxxxx
xxxx
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
1
2
3
45
6
7
89
0
M10895
120 OHM
120 OHM
KEYPAD KEYPAD
xxxxx
xxxx
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
1
2
3
45
6
7
89
0
xxxxx
xxxx
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
1
2
3
45
6
7
89
0
KEYPAD KEYPAD
TB-1
1
2
MAXIMUM SIGNAL DISTANCE 3000 FT MAXIMUM SIGNAL DISTANCE 3000 FT
SYSTEM 7000
CONTROL
Fig. 13. Star HBus wiring.
Hardwired Detection Circuits
The Honeywell 7000 System control panel and each PEM
has eight fully supervised hardwired input loops that can be
used for zoning groups of sensors or identifying individual
points of protection. These input loops can be programmed to
respond as the point types listed in Table 2.
Burglary Circuit Wiring
1. Use only UL-listed switches and sensors.
2. Use UL-listed wire, 22 AWG minimum.
3. Loop lengths are not to exceed 1000 feet.
4. Each circuit must be terminate with a 3.3K ohm,
1/4 watt EOLR (provided).
5. Make all connections according to the loop diagrams
that follow.
6. Program loops for type as well as NC or NO contact
operation.
xxxxx
xxxx
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
1
2
3
45
6
7
89
0
xxxxx
xxxx
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
1
2
3
45
6
7
89
0
M10896
120 OHM
KEYPAD KEYPAD
xxxxx
xxxx
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
1
2
3
45
6
7
89
0
xxxxx
xxxx
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
1
2
3
45
6
7
89
0
120 OHM
KEYPAD KEYPAD
xxxxx
xxxx
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
1
2
3
45
6
7
89
0
xxxxx
xxxx
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
1
2
3
45
6
7
89
0
120 OHM
KEYPAD KEYPAD
TB-1
1
2
SYSTEM 7000
CONTROL
5 6 7
N.O.
N.O.
EOLR
3.3K 5% 1/4W
TB1
P1
P2
CM
N
NORMALLY OPEN CONTACTS
5 6 7
N.C.
N.C.
EOLR
3.3K 5% 1/4W
TB1
P1
P2
CM
N
NORMALLY CLOSED CONTACTS
HARDWIRE LOOP WIRING P1 THROUGH P7
15 16
N.O.
N.O.
EOLR
5.1K 5% 1/4W
TB1
P8 –
P8 +
15 16
TB1
P8 –
P8 +
NORMALLY OPEN CONTACTS
N.C.
N.C.
EOLR
5.1K 5% 1/4W
NORMALLY CLOSED CONTACTS
(PERFERRED)
M10898
P8 HARDWIRE LOOP WIRING FOR BURGLARY
Fig. 14. Terminal Block TB1 hardwire loops.
Fig. 12. Dual branch HBus wiring.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell 7000 and is the answer not in the manual?

Honeywell 7000 Specifications

General IconGeneral
Battery BackupYes
Wireless CapabilityYes
Keypad Zones8
User Codes48
AutomationYes
Remote ControlYes
Power Supply120V AC
KeypadYes
CompatibilityHoneywell Total Connect

Related product manuals