Mounting and Wiring the Control
2-7
AUXILIARY DEVICE CURRENT DRAIN WORKSHEET
DEVICE CURRENT # UNITS TOTAL CURRENT
6128RF Keypad/Transceiver 90mA standby/120mA alarm
6150RF Keypad/Transceiver 80mA standby/105mA alarm
6148 Fixed-Word Keypad 30mA standby/55mA alarm
6150 Fixed-Word Keypad 40mA standby/90mA alarm
6160 Alpha Keypad 40mA standby/150mA alarm
6150V Fixed-Word Display
Voice Keypad
60mA standby/160mA alarm
6160V Alpha Display Voice
Keypad
60mA standby/190mA alarm
6164 Keypad w/4-Zone
Expander and Relay
115mA standby/190mA alarm
5881 RF Receiver 35mA
5883 RF Transceiver 80mA
4219 Zone Expander 35mA
4204 Relay Unit
15/180mA
4229 Zone Expander/Relay
Unit
35/100mA
TeleCommand 55mA (standby)
119mA (local phone)
85mA (remote phone)
*
*
TOTAL =
(Current available from Aux. terminals = 700mA max.)
*If using wired devices such as PIRs or Dual Tecs, refer to the specifications for that particular unit's
current drain.
Figures are for relays OFF/relays ON.