Installation and Setup Guide
2-18
V48A-V48E-001-V0
ABLE)
Figure 11. Trigger Module
Phone Line Connections
VISTA-12E
Connect incoming phone line and handset wiring
to the main terminal block (via an RJ31X jack) as
shown in the Summary of Connections diagram.
Wire colors represent the colors of the cable to the
RJ31X jack.
VISTA-12A
Plug the phone line plug into the modular phone
connector mounted on the PC board.
Notes
If you are using an Audio Alarm
Verification (AAV) unit, refer to Audio
Alarm Verification (AAV) section for
special wiring connections.
CAUTION: To reduce the risk of fire, use only
0.6mm O.D. or larger telecommunication line
cord for phone line connections.
Alternative Communications Media
(ACM) Connections
Connect the data in/data out terminals and voltage
input terminals of the ACM to the control's keypad
connection points.
Set the ACM’s address to “03” following the
instructions provided with the ACM.
Notes
Use compatible ACMs (e.g., 7845i,
AI4164RS, or AI4164ETH).