Installation and Setup Guide
5-4
PROMPT
VALID ENTRIES EXPLANATION
17 INPUT S/N: L
A022-4064 1
Serial number Entry and
Loop Number Entry
see explanation
[] to continue
Used only when enrolling wireless transmitters.
a. Transmit two open/close sequences. If using a
button-type transmitter, press and release the
button twice, but wait about 4 seconds before
pressing the button the second time.
OR
b. Manually enter the 7-digit serial number
printed on the label of the transmitter. Then
press the [] key – the cursor will move to the
“L” position. You can edit the loop number, if
necessary. When the loop number is
acceptable, press [].
c. Press key [C] to copy the serial number
previously enrolled (used when programming a
transmitter with several input loops).
17 INPUT S/N L
A022-4064 ?
Loop Number Change
[] to continue
NOTE: If the [C] key is used to copy the
previously enrolled serial number, the cursor will
move to the Loop column (L) with the previous
serial number displayed, and display a
highlighted question mark for the loop number.
Enter the loop number and press []. The system
will now check for a duplicate serial/loop number
combination.
17 INPUT S/N L
A022-4064 1
Enroll Summary
[] to continue
If the serial/loop number combination is not a
duplicate in the system, a display showing the
serial number and loop number entry will appear.
To Delete an Existing Serial Number: Enter 0
in the loop number field. The serial number will
change to 0's.
10 INPUT S/N: L
A000-0000 0
If 0 was entered in error, simply re-enter the loop
number or press [#], and the serial number will
return to the display.