5 FC1: Operation for Legally Relevant Functionalities
Page 32 of 61
Use in Legal Metrology
enCore FC1
C
Gas Quality
AFB
(main
display)
5
Cf. Table 12.
Qc
6
Flow rates QE Energy flow rate
QM Mass flow rate
Qb Base volume flow rate
Qc Corrected volume flow
rate
Qm Flow rate for volume at
measurement conditions
Cf Correction factor
Table 10: Contents of the Flow Conversion's fiscal display
The labels for all counters and additional measurements that are shown in
the Flow Conversion's main display are hyperlinks.
Figure 9 shows a typical example of a Flow Conversion main display; Table
11 lists the target displays of the hyperlinks as well as the values and
measurements included.
5
If the Flow Conversion AFB is linked to a Table Z AFB instead of a Gas Quality AFB,
the link leads to the main display of the corresponding Table Z AFB, cf. 5.4.3.
6
If no gas meter correction is parameterized, the flow rate Qm (uncorrected flow rate
at measurement conditions) is displayed instead of Qc. Within the target display, the
lines for Qc and the correction factor are omitted in that case.

Table of Contents

Other manuals for Honeywell enCore FC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell enCore FC Series and is the answer not in the manual?

Honeywell enCore FC Series Specifications

General IconGeneral
BrandHoneywell
ModelenCore FC Series
CategoryDesktop
LanguageEnglish

Related product manuals