Grounding
Warning
For proper grounding of the 854 ATG, install a copper strip under one of
the flange bolts for each flange.
Place shark rings between flange and strip (figure 4).
Figure 4 Example of flange ground
Note:
Also in case of tanks with cathodic protection, the 854 ATG must be grounded to the tank.
Cathodic protection can be maintained by isolating the cable screen/armouring or conduit.