Item Item Name & Description
417 P3 Pressure Span Factor
The most recent span value factor for P3 pressure transducer and obtained during a
pressure span calibration. The value is normally very close to 1.0000 and recalculated on
each pressure span calibration.
Default = 1.0000
418 P3 Pressure Previous Span Factor
The previous P3 span factor recorded in item 417, updated on each calibrat
ion.
Default: 1.0000
419 P3 Pressure Range User
The upper pressure range limit, automatically scaled to the pressure units selected at item
408. If PSI is the selected pressure units, then item 419 will be the same as item 412.
NOTE: The value at Item 419 and maybe manually edited to a rounded-off number, if
desired.
Default = 333.00
420 P3 Gas Pressure
Gas pressure measured at the las
t wake-up. The pressure reading is scaled to the unit of
measure selected at item 408.
421 P3 Average Pressure
P3 average pressure that occurred during the log interval
422 P3 Interval High Pressure
Highest P3 pressure reading recorded during the log interval.
423 P3 Interval Low Pressure
Lowest P3 pressure reading recorded during the log interval.
424 P3 Current Day Average Pressure
Av
erage P3 pressure readings recorded for the current day.
425 P3 Previous Day Average Pressure
Previous value recorded in item 424
426 P3 Maximum Pressure
Maximum P3 pressure reading recorded since the recorder was last reset.
Default: 0.000
427 P3 Maximum Pressure Time
Time of maximum P3 pressure reading was recorded since the recorder was last reset.
Default: 00 00 00
428 P3 Maximum Press
ure Date
Date of the maximum P3 pressure reading since the recorder was last reset.
Default: 01-01-04