51
Item Item Name & Description
573 P2 Pressure Range User
The upper pressure range limit, automatically scaled to the pressure units selected at item
550. If PSI is the selected pressure units, then item 573 will be the same as item 572.
NOTE: The value at item 573 may be manually edited to a rounded-off number, if
desired.
Default: 111.00
574 P1 Transducer Serial Number
Note: Forcing facto
ry defaults will not change the value of this item.
Default: 00000000
575 P2 Transducer Serial Number
Note: Forcing factory defaults will not change the value of this item.
Default: 00000000
576 Instrument Configuration
Selection that defines the number and type of transducers (pressure or temperature)
installed in a particular recorder. MasterLink32 uses this item to determine number
and
type of transducers installed in the recorder. If improperly configured will limit the
functionality of MasterLink32.
Code Value
Default: 1 P1
2
3 P1 & P2
4 T
5 P1 & T
7 P1, P2, & T
8 P1, P2, P3,
9 P1, P2, P3, & T
577 Recorder Serial Number
The numerical portion of the instrument's serial number label that is located in the inside
of door.
Disregard the leading zero, the first two digits indicate the year of manufacture,
and the last five digits are assigned sequentially from the beginning of the year.
Default: 0
578 Firmware Version
This item contains the recorder’s operating firmware version number. Automatically
insert when a firmware file it upload in the recorder.
579 Instrument Type
Use by MasterLink32 and other softwar
e programs that identifies the instrument type.
580 Site ID Number
First of two numeric fields that are used by MasterLink32 and other software programs to
identify the recorder and up to eight digits may be used and the only valid characters are
0-9.
Default: Instrument serial number