DF-60953:D • 3/27/2023 — Page 1 of 4
ES-50X Series
Intelligent Addressable
Fire Alarm Control Panels
Addressable Fire Alarm Control Panels
DF-60953:D
General
The ES-50X, ES-50XC, ES-50XI, and ES-50XP are the latest intelli-
gent addressable fire alarm control panel (FACPs) from Fire•Lite
Alarms and are direct replacement for the MS-9050UD. The ES-50X
Series support up to 50 addressable devices in any combination of
detectors or modules. With an extensive list of powerful features, the
ES-50X Series programs just like Fire•Lite’s other addressable panels,
yet
fits into applications previously served only by conventional panels.
The ES-50X and ES-50XC feature a pre-installed IPOTS-COM, a dual
technology (POTS and IP) communicator. The POTS transmits system
status (alarms, troubles, AC loss, etc.) to a Central Station via the pub-
lic switched telephone network. The IP communicator’s internet moni-
toring capability sends alarm signals over the Internet saving the
monthly cost of two dedicated business telephone lines. Although not
required, the secondary telephone line may be retained providing
backup communication over the public switched telephone line.
Optional cellular reporting is available using an HW-TG7F Series
Communicators or the CLSS Pathway.
The ES-50XP features an integrated CLSS Pathway Pro Communica-
tor, a dual-SIM (AT&T/ Verizon) 5G LTE-M Communicator with optional
IP connection. The CLSS Pathway Pro transmits system status
(alarms, troubles, AC loss, etc.) to the Central Station using LTE CAT-
M1 networks, serving as a bridge between the fire system and the
CLSS Cloud. The IP communicator's Internet monitoring capability
sends alarm signals over the Internet, meeting requirements for
backup communication. As an integrated communicator, the CLSS
Pathway Pro, typically, can transmit data faster than dial capture meth-
ods.
Remote and local programming of the control panel is possible using
the FS-Tools Upload/Download utility. Programming databases can be
uploaded/downloaded via the panel’s USB port (and USB cable) or via
an ethernet connection using the IPOTS-COM communicator (ES-50X
and EX-50XC only). The USB port also allows for the download or
upload of the entire program, history file, walk-test data, current status
and system voltages by means of a USB flash drive.
The power supply and all electronics are contained on a circuit board
supported on a new quick install chassis and housed in a metal cabi-
net. Available accessories include local and remote upload/download
software, remote annunciators, and reverse polarity/city box transmit-
ter (4XTMF).
Features
Listed to UL Standard 864, 10th edition
Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele-
phone Service) Central Station Communicator (ES-50X and EX-
50XC only)
Optional Cellular Central Station Communicators over AlarmNet®
(ES-50X and EX-50XC only)
Integrated CLSS Pathway Pro Communicator; dual SIM AT&T/Veri-
zon networks with LTE-CAT-M1 5G technology (EX-50XP only)
Cloud monitoring using Honeywell’s Connected Life Safety Ser-
vices (CLSS) Cloud solutions software (EX-50XP only)
Compatible with SWIFT® wireless devices
Auto-programming (learn mode) reduces installation time. Reports
two devices set to the same address
Two independently programmable, built-in, Class A or Class B NAC
circuits
Selectable strobe synchronization for System Sensor, Wheelock,
and Gentex devices
Notification Appliance Circuit End of Line resistor matching
Four programmable function keys for ease of maintenance
Two programmable relays and one fixed trouble relay
Built-in Programmer
Integral 80-character LCD display with backlighting
Real-time clock/calendar with automatic daylight savings control
History file with 1,000 event capacity
Addressable sounder base
Multi-criteria detector (smoke, heat, CO) with programmable
response
Control module delay timer
Automatic detector sensitivity testing (NFPA 72 compliant)
Automatic device type-code verification
Point trouble identification
Waterflow selection per module point
Alarm verification selection per detector point
Maintenance alert warns when smoke detector dust accumulation
is excessive
One-person audible or silent walktest with walktest log & printout
System alarm verification selection per detector point
PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72
compliant)
Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus
Remote Acknowledge, Alarm Silence, Reset and Drill via address-
able modules or remote annunciator
Upload/Download of program and data via USB with optional
FS-Tools Programming Utility
SLC (DCL) COMMUNICATION LOOP
Supports LiteSpeed™ and CLIP protocols
SLC (DCL) operates up to 10,000 ft. (3,000 m) in LiteSpeed mode
with twisted, unshielded wire
Single addressable SLC (DCL) loop which meets NFPA Class B
and Class A requirements
50 addressable device capacity (any combination of addressable
detectors and modules)
Compatible with Fire•Lite’s addressable devices (refer to the SLC
Wiring Manual)
Question and Answer IconNeed help?

Do you have a question about the Honeywell FIRE-LITE ALARMS ES-50X Series and is the answer not in the manual?

Honeywell FIRE-LITE ALARMS ES-50X Series Specifications

General IconGeneral
BrandHoneywell
ModelFIRE-LITE ALARMS ES-50X Series
CategoryControl Panel
LanguageEnglish

Summary

General ES-50X Series Overview

IPOTS-COM Communicator Functionality

Dual technology (POTS and IP) communicator for system status transmission via public switched telephone network and internet.

CLSS Pathway Pro Communicator Features

Integrated communicator for LTE-M networks, providing cloud monitoring and faster data transmission.

Programming Methods

Remote and local programming via USB or Ethernet using the FS-Tools utility.

ES-50X Series Key Features

UL 864 10th Edition Compliance

Listed to UL Standard 864, 10th edition, ensuring compliance with fire alarm system requirements.

Integrated Communication Options

Features pre-installed IPOTS-COM and optional CLSS Pathway Pro for central station communication.

Installation and Configuration

Supports auto-programming (learn mode) and offers two programmable NAC circuits.

System Monitoring and Diagnostics

Includes maintenance alerts for dust accumulation and point trouble identification.

Advanced Features and Compliance

Supports PAS, pre-signal per point, and NFPA 72 requirements for advanced fire control.

SLC (DCL) Communication Loop Capabilities

Supported Communication Protocols

Supports LiteSpeed™ and CLIP protocols for addressable device communication.

LiteSpeed Mode Operation

SLC operates up to 10,000 ft in LiteSpeed mode with twisted, unshielded wire.

Addressable Device Capacity

Supports a capacity of 50 addressable devices in any combination of detectors and modules.

Notification Appliance Circuits (NACs)

NAC Circuit Configuration

Two independently programmable circuits, configurable for Class A or Class B wiring.

NAC Output Capabilities

Supports continuous, march time, temporal, or California code with selectable strobe synchronization.

Programming and Software Utilities

FS-Tools Programming Software

Windows-based software for creating, uploading, and downloading panel programs.

Offline Programming

Create and manage panel programs offline via an Ethernet connection.

User Interface Elements

LED Indicators

Provides visual status indication for Fire Alarm, Trouble, AC Power, and other system states.

Keypad Functions

Features an alpha-numeric keypad and programmable function keys for system control.

Product Line and Model Information

ES-50X Series Models

Details on ES-50X, ES-50XC, ES-50XI, and ES-50XP panel configurations.

Optional Communicator Modules

Information on IPOTS-COM and CLSS Pathway Pro communicator options.

Optional Accessories

Lists optional accessories like dress panels, trim rings, and battery backboxes.

Addressable Devices and Modules

Addressable Smoke and Heat Detectors

Details on various addressable photoelectric, thermal, and multi-criteria detectors.

Addressable Control and Monitor Modules

Information on monitor, control, and relay modules for system expansion.

Addressable Accessories

Includes end-of-line resistors and power supervision relays for system supervision.

System Specifications

System Capacity Details

Specifies system capacity for signaling line circuits, devices, zones, and annunciators.

Electrical and Power Requirements

Details AC power input, battery requirements, and communication loop specifications.

Cabinet and Shipping Information

Provides dimensions for cabinet, backbox, and trim ring, along with shipping weight.

Temperature and Humidity Ranges

Specifies operating temperature and humidity ranges and recommendations for optimal performance.

NFPA Standards and Agency Approvals

NFPA 72 Compliance

Details compliance with various NFPA 72 Fire Alarm Systems requirements.

Agency Listings and Approvals

Lists UL, FM, CSFM, and FDNY approvals for the ES-50X control panel.