C2
P/N 52626:C2 ECN 12-056
Document 52626
1/24/2012 Rev:
Fire Alarm Control Panels
MS-5UD Series
MS-10UD Series
Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Honeywell Fire-Lite Alarms MS-5UD Series and is the answer not in the manual?

Honeywell Fire-Lite Alarms MS-5UD Series Specifications

General IconGeneral
Number of Zones5
Dimensions14.5" (36.83 cm) H x 12.75" (32.39 cm) W x 3.5" (8.89 cm) D
Weight11 lbs (5 kg) without batteries
Zone ConfigurationClass B
Operating Temperature32°F to 120°F (0°C to 49°C)
TypeControl Panel
CompatibilityCompatible with Fire-Lite devices
Compatible DevicesFire-Lite detectors, modules, and other compatible devices
CommunicationOptional dialer
Standby Current150 mA
Auxiliary Power Output24 VDC, 500 mA
Humidity Range10% to 93% non-condensing

Summary

Fire Alarm System Limitations

Smoke & Heat Detector Limitations

Describes where smoke detectors may fail and heat detector maintenance.

Audible & Visual Device Considerations

Discusses limitations of warning devices and user response.

System Power & Reliability

Covers AC power dependence and battery backup.

Installation Precautions & Guidelines

System Setup & Testing

Covers power disconnect, software testing, and environmental specs.

Static Discharge Prevention

Guidelines for handling static-sensitive components.

Section 1: Product Description

Key Product Features

Lists the main capabilities and versions of the FACP.

Technical Specifications

Details AC power, current draw, and other technical parameters.

Controls, Indicators & Components

Describes panel interface elements and core parts.

Optional Modules & Accessories

Lists available add-ons and their functions.

Section 2: Installation

Cabinet Mounting & Power Setup

Covers backbox mounting and AC/battery power connections.

Input & Output Circuit Wiring

Details connecting initiating devices and notification appliances.

Special Wiring Requirements

Covers power-limited wiring and digital communicator setup.

Installing Optional Modules

Guides for adding converter, transmitter, and ANN-BUS modules.

ANN-BUS Device Configuration

Covers ANN-BUS wiring, addressing, and device setup.

Section 3: Programming

Programming Methods & Initial Setup

Overview of user/remote/local programming and initial power-up.

Master Programming Level

Navigating and configuring system settings via keypad.

Input Zone & NAC Configuration

Programming specific input zones and notification appliance circuits.

Relay & System Setup Configuration

Configuring relay functions and system-wide settings.

Option Module & DACT Programming

Configuring ANN-BUS modules and the digital communicator.

Section 4: Operating Instructions

Panel Controls & Indicators

Explains button functions and LED meanings.

System Operational Modes

Describes normal, trouble, alarm, and supervisory operations.

Special System Functions

Details hazard, medical, waterflow, and detector functions.

Testing & Status Viewing

Covers walktesting and reading system status.

Section 5: Central Station Communications

Reporting Priorities & Compatibility

Event priority order and compatible receivers.

Section 6: Local/Remote Site Upload/Download

Upload/Download Procedures

Steps for transferring programs and data.

Security Features for Transfers

Details on code verification and data protection.

Section 7: Power Supply Calculations

AC Branch Circuit & System Current Draw

Calculating power requirements and current loads.

Battery Size Calculation

Determining battery capacity based on NFPA standards.

Appendix A: Ademco Contact ID Format Event Code Descriptions

Contact ID Transmission & Reporting

Format details and typical printout examples.

Appendix B: NFPA Standard-Specific Requirements

NFPA 72 Compliance Requirements

Equipment and configurations for NFPA 72 standards.

Appendix F: Canadian Application

ANN-LED Annunciator for Canada

Specific installation notes for Canadian models.