Emergency operation when batteries are flat
1. Unlock the radiator controller. To do so, push the slide
at the radiator controller towards .
2. Pull the radiator controller off the valve baseplate.
3. Operate the radiator valve by hand using the
adjustment dial on the baseplate.
–
+
Restoring the factory setting
1. Keep the button pressed for approximately
5 seconds until Parameter 1 flashes (left-hand digit).
2. Use the adjustment dial to select Parameter 12 (left-
hand digit) and Setting 1 (right-hand digit).
3. Press the button to restore the factory setting.
The binding is retained.
4. Use Exit to return to normal operation.
8. Technical data
Type HR92UK
Protection class IP30
Radio communication ISM (868.0 ... 870.0 MHz)
RX Class 2
Range: typically 30 m within
residential buildings
Supply voltage Battery type LR6, AA, AM3
Alkaline: 2 x 1.5 V
Lithium: 2 x 1.5 V
NiMH: 2 x 1.2 V
Connection to the radiator M30 x 1.5
Ambient temperature 0 ... 50 °C
Dimensions 96 x 54 x 60 mm
Ambient conditions For living area, business and
commercial areas as well as
small businesses
Humidity 10 ... 90 % rel. humidity
9. Disposal
The radiator controller has to be disposed of in
accordance with WEEE directive 2002/96/EC – Waste
Electrical and Electronic Equipment directive.
f Dispose of the packaging and product
in a corresponding recycling centre.
f Do not dispose of the unit with the
domestic refuse.
f Do not burn the product.
10. Declaration of Conformity
Hereby Honeywell declares that this HR92UK is in
compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC.