Configuring Alarm Settings | 85
800-16694 - A - 04/2014
6. Click the Handling button to set up the alarm response actions. The Handling window
opens.
a. Under Trigger Channel, select the channel(s) you want to begin full-screen
monitoring or recording video with when the alarm input generates an alarm signal, or
click Analog to select all the channels, and then click Apply to save your settings.
Note To automatically start recording video on the channel when an alarm input event
is detected, you must set the recording schedule to Alarm, Motion|Alarm, or
Motion & Alarm. See Configuring a Record Schedule, page 56.
b. Click the Arming Schedule tab to set the arming schedule of the alarm input. You can
set up to eight time periods per day (the time periods cannot repeat or overlap). To
copy the arming schedule to other days of the week, click Copy. Click Apply to save
your settings.