Specifications
LYNX Touch Series Security Controls
Physical:
Dimensions: 8.5” W x 6” H x 1.875” D
Electrical:
Voltage Input: 9 Vdc from plug-in 2.7A power supply
Rechargeable Backup Battery: Nickel-metal hydride battery pack rated at 7.2 Vdc
Communication:
Formats Supported: ADEMCO Contact ID® Reporting, 10 characters/sec., DTMF (TouchTone)
Data Tones, 1400/2300Hz Handshake, 1400Hz Kissoff.
SIA/DCS Format, 2225Hz Handshake, Data Tones, 2025/2235Hz, baud
Line Seize: Double Pole
Ringer Equivalence: 0.5B
ACTA Registration No.: US: AC3AL05BL5000
Hardwire Zone: 2K ohms, End of Line Resistor (EOLR), 200 ohms max wire resistance, dry
contacts only
Trigger Output: 1k ohms to ground when closed (output low) 3ma