Lyric Controller Installation and Reference Guide
- 35 -
Agency
AgencyAgency
Agency
Notices
NoticesNotices
Notices
1. For Residential Burglar Alarm installations with line security, total exit delay time must not exceed 60
seconds. For Burglar Alarm installations without line security, total exit delay time must not exceed 120
seconds.
2. Periodic testing must be at least every 24 hours.
3. Remote downloading without an alarm company technician on-site (unattended downloading) is not
permissible for ETL installations.
4. As SIA limits for delay of alarm reporting and sounding can exceed UL Standard limits for commercial and
residential applications, the following requirements per UL681 are provided:
The maximum time that a control unit shall be programmed to delay the transmission of a signal to a
remote monitoring location, or to delay the energizing of a local alarm sounding device to permit the
alarm system user to enter and disarm the system, or to arm the system and exit shall not exceed:
a) 60 seconds for a system with standard line security or encrypted line security,
b) 120 seconds for a system without standard line security or encrypted line security, or
c) 120 seconds for a system that does not transmit an alarm signal to a remote monitoring location.
SIA Quick Reference Guide
SIA Quick Reference GuideSIA Quick Reference Guide
SIA Quick Reference Guide
Programming Section
Programming SectionProgramming Section
Programming Section Feature
FeatureFeature
Feature Ra
RaRa
Range
ngenge
nge Shipping Default
Shipping DefaultShipping Default
Shipping Default SIA Requirement
SIA RequirementSIA Requirement
SIA Requirement
Installation and Setup Guide or Programming Guide
Installation and Setup Guide or Programming GuideInstallation and Setup Guide or Programming Guide
Installation and Setup Guide or Programming Guide
Reporter
ReporterReporter
Reporter/
Report Selection
Exit Error Not selectable Enabled Enabled
Recent Closing Not selectable Enabled Enabled
Alarm Cancel Enabled or Disabled Enabled Enabled
Reporter
ReporterReporter
Reporter/Options Number of
Reports
1 to 6 Reports 2 Reports 2 Reports
Alarm Report
Delay (Abort
Window)
15, 30 and 45 seconds 30 seconds 30 seconds*
System Settings
System SettingsSystem Settings
System Settings Entry Delay # 1 None, 15, 30, 45, 60 and
90 seconds and 2, 3 or
4 minutes
30 seconds 30 seconds minimum
Entry Delay # 2 None, 15, 30, 45, 60 and
90 seconds and 2, 3 or
4 minutes
30 seconds 30 seconds minimum
Exit Delay 45, 60, 90 seconds and
2 minutes
60 Seconds 45 seconds minimum
Restart Exit Time Enabled or Disabled Yes (Enabled) Enabled
Exit Warning Not selectable Yes (Enabled) Enabled
Auto Stay
Arming
Enabled or Disabled Yes (Enabled) Enabled
Cross Zone Delay 30 seconds and 2
minutes (in 30 second
increments), 3 minutes
and 4 minutes
None (Disabled) Enabled and two zones
programmed
Zones
ZonesZones
Zones Fire Alarms Zone Type “Fire with
Verification” must be
selected for Fire Zone
95
Disabled Disabled
User Guide
User GuideUser Guide
User Guide
User Functions/
User Functions/User Functions/
User Functions/
User Access
Duress Duress Code is
Programmed by Master
User as User 48
Disabled Disabled
System Functions/
System Functions/System Functions/
System Functions/
Testing the System**
System Test System tests provided
as a User Function
n/a n/a
Communications While the system is in
Test mode, no alarm
reports are sent to the
Central Station
Disabled Disabled
* Combined Entry Delay and Alarm Report Delay (Abort Window) should not exceed 1 minute.
** Refer to the User Guide for procedures on Testing the System.