www.honeywellsafety.com page 11 of 24
C7. Connecting the fall arrester to the full body harness:
1.
Pull-down the knurled bushing (4.1)
of
the
karabiner.
2. Then turn the knurled bushing and press it
inwards.
3.
Attach
it
directly
in
the attachment point
of
the full body
harness.
4. Release the knurled bushing, it locks
automatically.
Fig. C1
C8.
Danger!
An unsecured karabiner (open knurled bushing) is dangerous to
human
life
.
C9. The abdominal or thoracic strap of the full body harness must fit the
body tightly (see Fig. C1).
Fig. C2
C10.
Danger!
The karabiner of the fall arrester must be directly inserted into the
front attachment point of
the
full body harness. The length
of
the
intermediate joint (length between the cable and the
inner
curve
of
the eye
on
the harness) must not exceed 200
mm.
Fall arrester D-ring
attachment
element
attachment
element
front D-ring of
harness
harness
body
correct
incorrect