EasyManuals Logo

Honeywell MK VIII Pilot's Guide

Honeywell MK VIII
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
060-4314-000 • Rev. C - May 2004
MK VI & MK VIII EGPWS Pilot Guide
25
Bank Angle Turbofan (Jet)
• ±10 degrees between 5 and 30 feet AGL,
• ±10 to ±40 degrees between 30 and 150 feet AGL,
±40 to ±55 degrees between 150 and 2450 feet AGL,
With the AutoPilot engaged, bank angles exceeding:
±10 degrees between 5 and 30 feet AGL,
• ±10 to ±33 degrees between 30 and 122 feet AGL,
±33 degrees above 122 feet AGL,
Once the initial roll limit is exceeded, the “BANK ANGLE, BANK
ANGLE” callout is given once. Another callout is not given until
either:
1) a 20% increase in roll is detected, or
2) the aircraft rolls below the initial roll limit (resetting the pro
-
cess) and initial roll limit is exceeded again.
If the 20% increase in roll is exceeded (causing the second bank
angle alert), another callout is not given until either:
1) another 20% increase in roll is detected, or
2) the aircraft rolls below the initial roll limit and another (re
-
setting the process) and the initial roll is exceeded again.
Above the second 20% increase in roll, the callout is continuous
until roll is reduced below this second 20% limit.
If roll rate exceeds the audio callout time, then the bypassed
limit is not indicated (e.g., if a 20% increase is exceeded before
the initial roll limit callout can be completed). Another consid-
eration is the banking affect on Radio Altitude data during lower
altitude turning operations. Higher bank angles will increase the
MODE 6
Continued
33
33
122’
A/P ENGAGED
A/P ENGAGED

Other manuals for Honeywell MK VIII