Do you have a question about the Honeywell Notifier NFS-320 and is the answer not in the manual?
Model | NFS-320 |
---|---|
Type | Fire Alarm Control Panel |
Operating Temperature | 32°F to 120°F (0°C to 49°C) |
NAC Circuits Power | 2.5 A |
Relays | 2 |
Display | 80-character LCD |
Power Supply | Integrated |
Communication | RS-485 |
Dimensions | 14.5" x 3.5" |
Relative Humidity | 10% to 93% non-condensing |
Compliance | UL 864 |
SLC Loops | 1 |
Operating Voltage | 120VAC or 240VAC, 50/60 Hz |
Details on high-speed and standard network configurations for system expansion.
Describes the self-healing mesh wireless protocol and device support.
Details on independent hazards, cross-zone, and timers for releasing applications.
Covers FlashScan polling, device activation, and digital protocol benefits.
Details ONYX Intelligent Sensing, drift compensation, and multi-detector logic.
Explains fallback operation and automatic sensitivity testing compliance.
Description of FSV-951 VIEW detector, its sensing algorithms, and ULC listing.
Details on the FCO-951 detector detecting smoke, heat, CO, and flame.
Information on the FPTI-951 detector with photo, thermal, and infrared sensors.
Details on the FPC-951 detector combining photoelectric and CO sensing.
How drift compensation and filters maintain detector performance and resist false alarms.
Manual and automatic sensitivity levels, including self-optimizing pre-alarm.
Patented feature allowing sensors to share readings for improved alarm decisions.
Timesaving feature that automatically loads device parameters for installation.
Capability for program creation and editing from the front panel keypad.
Offline programming and test utility for site-specific software creation and management.
Guidelines for separating power-limited and non-power-limited wiring in cabinets.
Requirements for installing network communication modules in panels.
Overview of system assembly, configuration, and network requirements.
Details on the standard NFS-320 system components and available versions.
List of available network communication modules and repeaters.
Information on compatible auxiliary power supplies and battery requirements.
Details on the NFC-50/100 emergency Voice Evacuation Control Panel.
List of compatible devices and interfaces for EIA-232 serial data links.
List of compatible annunciators and modules for EIA-485 communication.
Addressable gateway supporting wireless SLC devices, not for ULC applications.
Details on FCO-951, FPC-951, and FPTI-951 intelligent detectors.
Information on FSCO-951 CO sensor and FSV-951 high-sensitivity smoke detector.
Details on FST-951 series fixed and rate-of-rise thermal sensors.
Information on FSP-951 series low-profile photoelectric sensors.
Details on VEP and VEU series aspiration detectors with LED/LCD displays.
Information on FS-OSI-RI addressable intelligent single-ended beam smoke detector.
List of available mounting bases for intelligent detectors, including sounder bases.
System for protecting equipment in shipboard and waterfront applications.
Information on NFS-LBB battery boxes and seismic mounting kits.
List of flush and surface mount backboxes for annunciators.
Details on UDACT-2 and 411UDAC Digital Alarm Communicators.
Module for internet communications via Ethernet connection.
Information on LTE Digital Cellular Fire Alarm Communicators.
Details on NFS-320 replacement boards and CPU options.
Overview of system capacity including circuits, detectors, and annunciators.
Information on primary input power, current draw, and output power.
Dimensions and weight details for the NFS-320 backbox and door.
Recommended operating environmental conditions for the system.
List of UL, ULC, FM, CSFM, and other agency approvals for the NFS-320.
Details on USCG, Lloyd's Register, and ABS type approvals for marine systems.
List of UL, ULC, NFPA, IBC, and CBC standards the NFS-320 complies with.