Page 2 of 7 — DN-7112:P • 12/20/2020
VOICE FEATURES
Integrates with FirstCommand Series. See DN-60772.
Telephone applications require NFC-FFT.
HIGH-EFFICIENCY OFFLINE SWITCHING
3.0 A P
OWER SUPPLY (6.0 A IN ALARM)
120 VAC (NFS-320/NFS-320C); 240 VAC (NFS-320E).
Displays battery current/voltage on panel (with display).
FLASHSCAN
®
INTELLIGENT FEATURES
Polls up to 318 devices in less than two seconds.
Activates up to 159 outputs in less than five seconds.
Multicolor LEDs blink device address during Walk Test.
Fully digital, high-precision protocol (U.S. Patent 5,539,389).
Manual sensitivity adjustment — up to nine levels.
Pre-alarm ONYX intelligent sensing — up to nine levels.
Day/Night automatic sensitivity adjustment.
Sensitivity levels:
–Photo 0.5 to 2.35%/foot obscuration.
High-Sensitivity Photoelectric (VIEW
®
) – Open Air Protection
(0.5% - 2.0%/ft. obscuration), Special Applications (0.02%-
0.5%/ft. obscuration)
Multi-Criteria Detector – Open Air Protection (2.52-3.89%/ft.
obscuration), Special Applications (1.13-2.52%/ft. obscuration)
Drift compensation (U.S. Patent 5,764,142).
Degraded mode: In the unlikely event that the NFS-320’s primary
microprocessor fails, FlashScan detectors revert to degraded
operation and can activate the control panel’s NAC circuits and
alarm relay. Each of the four built-in panel circuits includes a Dis-
able/Enable switch for this feature.
Multi-detector algorithm involves nearby detectors in alarm deci-
sion (U.S. Patent 5,627,515).
Automatic detector sensitivity testing (NFPA-72 compliant).
Maintenance alert (two levels).
Self-optimizing pre-alarm.
FSV-951 SERIES VIEW
®
(VERY INTELLIGENT EARLY WARNING)
H
IGH-SENSITIVITY SMOKE DETECTOR
Advanced ONYX intelligent sensing algorithms differentiate
between smoke and non-smoke signals.
Addressable operation pinpoints the fire location.
Ivory models (-IV) support CLIP mode as well as FlashScan.
ULC listed models available; “A” models are ULC Listed.
-R is retrofit, backwards compatible for use with older panels.
FCO-951/-IV ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR
Detects all four major elements of a fire (smoke, heat, CO, and
flame).
135°F (57.2°C) fixed-temperature heat detector.
Transmits an alarm signal due to heat.
Separate signal for life-safety CO detection.
Optional addressable sounder base for Temp-3 (fire) or Temp-4
(CO) tone.
Automatic drift compensation of smoke sensor and CO cell.
High nuisance-alarm immunity.
ULC listed models available; -A models are ULC Listed.
FPTI-951(A) INTELLIGENT MULTI-CRITERIA DETECTOR
Combined photoelectric, thermal, and infrared sensor
UL 268 7th Edition and UL 521 Listed; Canadian models CAN/
ULC S529 and CAN/ULC S530
Microprocessor-based technology; combination photo, thermal,
and infrared technology.
FPC-951(A) PHOTOELECTRIC/CO SENSOR
Combined photoelectric and carbon monoxide sensor
Sample
System
Options
7112blok-2014.wmf
SLC Intelligent Loop
DEVICES
FPTI-951
FSP-951
FST-951
FCO-951
…etc.
NBG-12LX
FMM-1
IDC
FDU-80
LCD2-80
Up to 32 remote displays
EIA-485
EIA-485
EIA-232
2048 annunciator/control points
Optional 318-point UDACT
Dual phone
lines to
Central
Station
ACM/AEM-24AT
LED Annunciator
LDM-32
Custom Graphics
ACM-8R
Relay Control
FCM-1
NAC
FRM-1
Relay Contact
PRN Series
Printer
NFS-320
FWSG
XP6/10
Input/Output Modules

Other manuals for Honeywell Notifier NFS-320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Notifier NFS-320 and is the answer not in the manual?

Honeywell Notifier NFS-320 Specifications

General IconGeneral
BrandHoneywell
ModelNotifier NFS-320
CategoryControl Panel
LanguageEnglish

Related product manuals