OELD Operating Instructions
10 Specifications
OELD Specification
Safety Approvals
ATEX [DEMKO 16 ATEX 1693X]
II 2 GD
Ex db IIC T6 (flameproof Ex d version)
Ex tb IIIC T85°C (flameproof Ex d version)
Tamb 40 to +65°C
cULus [E484838]
Class I, Division 1, Groups A, B, C and D
Class II, Division 1, Groups F and G
Class III, Division 1
Tamb 55 to +65°C, Temp Code T6, IP66, Type 4X
Class I, Zone 1, AEx d IIC T6
Class I, Zone 21, AEx tb IIIC T6
IECEx [IECEx UL 16 0066X]
Ex db IIC T6 (flameproof Ex d version)
Ex tb IIIC T85°C (flameproof Ex d version)
Tamb 40 to +65°C
CU TREx (Russian Customs Union), Tamb 60 to +65°C*
CCCF*
Inmetro [DNV 17.0010X]*
NEPSI+*
ISA 60079291
EN60079291 approved accessory
Maritime Approvals*
Type approved to DNV, BV+, Lloyds+, ABS
EN 60945 (EMC)
IEC 60092504
Other Approvals Bluethooth® certified, RED, FCC+, country-specific wireless approvals
Bluetooth®
communication security
Certificate-based mutual authentication. Encryption to AES128.
Note
+flameproof versions only
*Contact Honeywell Analytics for availability
Gas Performance: ISA 60079291 approved for methane gas only