28
SCANNER AND CABLE TERMINATIONS
Cable Connector Configurations (Host End)
“Standard” PowerLink Cable
PN 59-59000
x
-3 straight
Pin
Function
9-Pin D-Type Connector
1 Shield Ground
2 RS232 Transmit Output
3 RS232 Receive Input
4 DTR Input
5 Power/Signal Ground
6
Light Pen Data
7 CTS Input
8 RTS Output
9 +5VDC
USB Power/Communication Cable
PN 54-54213
x
-N-3,
54-54214
x
-N-3 or 59-59235
x
-N-3
Pin
Function
Locking, Type A
PN 54-54213
x
-N-3 or
PN 54-54214
x
-N-3
Non-Locking, Type A
PN
54-54214
x
-N-3
1
PC +5V/V_USB
2
D-
3
D+
4
Ground
Shield
Shield
Stand Alone Keyboard PowerLink
Cable PN 59-59020
x
-3
Pin
Function
6-Pin Male Mini-DIN Connector
1
PC Data
2
No Connect
3
Power Ground
4
+5VDC PC Power to KB
5
PC Clock
6
No Connect