14 PRO-2200 Output Module PRO22OUTInstallation Guide
Specification
The Output board is for use in low voltage, class 2 circuits only.
Primary power:
12 VDC±10% 400mA
Relay contacts:
Relays 1 through 16 outputs, Form-C, 2A @ 28 VDC, resistive
Inputs:
Two unsupervised dedicated inputs
Communication:
RS-485: Range 9,600 to 38,400bps
Wire requirements:
Power 1 twisted pair, 18AWG
RS-485 24AWG, 4,000feet (1,200m) max.,
2 (120, 23pF) twisted pair with shield (Belden 9842 or equiv.)
Alarm inputs 1 twisted pair per input, 30 ohms max.
Outputs As required for the load
Mechanical:
Dimension 5.5" (140mm) W x 9" (229mm) L x 1" (25mm) H
Weight 12 oz. (340g) nominal
Environment:
Temperature 0°C to +49°C, operating, -55°C to +85°C, storage
Humidity 0% to 85% RHNC