RTH6350/RTH6450 Series
15 69-2416ES—05
SETUP WIRING ASSISTANCE TROUBLESHOOTING
Function 2: Heat pump changeover valve
Done Next
2
0
M28352
Press the s or t button to select whether your
changeover valve is used in heating or cooling:
NOTE: If Function 2 does not appear, please turn to the
next page to continue.
0 Cooling changeover valve: Use this setting if
you connected a wire labeled “O” to the O/B wire
terminal (see page 21).
1 Heating changeover valve: Use this setting if
you connected a wire labeled “B” to the O/B wire
terminal (see page 21).
M28351
Press to change setting.
When correct setting is
selected, press NEXT to
display next function.