Do you have a question about the Honeywell RAEGuard 2 PID and is the answer not in the manual?
Detailed technical specifications including basic, environmental, physical, and certification parameters.
Instructions and diagrams for mounting the RAEGuard 2 PID unit to walls or poles.
Step-by-step guide for safely taking apart the RAEGuard 2 PID for servicing and maintenance.
Details on connecting the RAEGuard 2 PID to peripheral equipment using terminal blocks.
Step-by-step instructions for connecting wires to the terminal blocks for proper operation.
Procedures for proper external and internal earth grounding of the RAEGuard 2 PID.
Configuration of alarm relays (normally open/closed) for external signals like lights or buzzers.
Overview of the RAEGuard 2 PID's display, status LED, and magnetic key interface.
Description of the magnetic key used for interacting with the device's interface.
Instructions on how to use the magnetic key to navigate the RAEGuard 2 PID interface.
Describes the startup sequence, self-test, and warm-up process of the RAEGuard 2 PID.
Explains how the RAEGuard 2 PID displays gas concentration and status indicators.
Details on interpreting the various status indicators, LEDs, and LCD messages on the device.
Detailed technical specifications including basic, environmental, physical, and certification parameters.
Instructions and diagrams for mounting the RAEGuard 2 PID unit to walls or poles.
Step-by-step guide for safely taking apart the RAEGuard 2 PID for servicing and maintenance.
Details on connecting the RAEGuard 2 PID to peripheral equipment using terminal blocks.
Step-by-step instructions for connecting wires to the terminal blocks for proper operation.
Procedures for proper external and internal earth grounding of the RAEGuard 2 PID.
Configuration of alarm relays (normally open/closed) for external signals like lights or buzzers.
Overview of the RAEGuard 2 PID's display, status LED, and magnetic key interface.
Description of the magnetic key used for interacting with the device's interface.
Instructions on how to use the magnetic key to navigate the RAEGuard 2 PID interface.
Describes the startup sequence, self-test, and warm-up process of the RAEGuard 2 PID.
Explains how the RAEGuard 2 PID displays gas concentration and status indicators.
Details on interpreting the various status indicators, LEDs, and LCD messages on the device.
| Sensor Type | Photoionization Detector (PID) |
|---|---|
| Target Gas | Volatile Organic Compounds (VOCs) |
| Operating Temperature | -20°C to +50°C (-4°F to +122°F) |
| Output Signal | 4-20 mA, RS-485 Modbus |
| Ingress Protection | IP65 |
| Operating Humidity | 0 to 95% RH (non-condensing) |
| Display | LCD |