36 ScanPal EDA61K Mobile Computer
Imager Settings
You should not need to modify the Imager Settings. The Override Recommended
Values setting is disabled by default. The recommended Imager Settings are
designed to work in a wide range of environments and should only be modified if
you have an advanced understanding of imagers.
Video Mode Use this setting to specify whether normal or inverse decoding for
linear symbologies is enabled during the execution of Decode. By
default normal video is enabled.
Options include:
Normal
Inverse
Normal and Inverse
Normal
DPM mode Use this setting when scanning Direct Part Marking (DPM)
barcodes that are etched or imprinted directly into the surfaces of
materials including metal and plastic.
Options include:
No DPM optimization
Dotpeen DPM decoding
Reflective DPM decoding
No
optimiza
tion
Region of Interest Set the ROI for decoding. Options include:
Disable
ROI is disabled and the entire original image is sent to the
decoder.
Standard
Use the aimer position to weight activity. Activity
calculated on the row and the column in the middle of
each cell. The ROI window may not include the aimer.
Standard, aimer centered
Activity calculated on the row and the column in the
middle of each cell. The ROI window will always include
the aimer.
DPM, aimer centered
Activity calculated on 4 rows and 2 columns in each cell.
The ROI window will always include the aimer.
Kiosk/presentation application
Ignore aimer position, no weight activity. Activity
calculated on the row and the column in the middle of
each cell. The ROI window may not include the aimer.
Learning Engine
When selected, the computer will receive continuous
updates to improve the decoder software based on your
specific environment. The Staging Hub Agent must also
be enabled.
Disabled
Setting Description Default

Table of Contents

Other manuals for Honeywell ScanPal EDA61K Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell ScanPal EDA61K Series and is the answer not in the manual?

Honeywell ScanPal EDA61K Series Specifications

General IconGeneral
BrandHoneywell
ModelScanPal EDA61K Series
CategoryHandhelds
LanguageEnglish

Related product manuals