4.
INMARSAT Operational
A. General
(1)Class15Services.
StandardIP
StreamingIP
BGANIPVoice
Combinationsoftheabove.
(2)Background,streamingandsubscriptiontraffic classesaresupported.
(3)Userisabletosetup1primaryandupto9PDPcontextsonaconnection.
PrimaryandsecondaryconnectionscanbesetupviatheRESTfulinterface
TheWebUIcanonlysetupaprimaryconnection
5.
USIM
A. General
(1)WhenauserinsertsorremovesaSIMcard,theindoorunitwillreset.
(2)TheterminalworkswithanInmarsatclass15USIMAeronauticalprovidedbytheHoneywell
serviceproviderandtheHoneywelldistributionpartner.
6.
LED Indicator
A. Indications are as listed below:
(1)NoPowerOff
(2)OKGreen
(3)Error-Red
7.
Temperature Profile
A. Antenna
(1)Theantennawillsurvivethroughatemperaturerangeof-55to85°C(-67to185°F).
(2)Theantennawilloperatethroughanenvironmentaltemperaturerangeof-40to55°C(-40
to131°F).
B. Indoor Unit
(1)Theindoorunitwillsurvivethroughatemperaturerangeof-55to85°C(-67to185°F).
(2)TheIndoorUnitwilloperatethroughanenvironmentaltemperaturerangeof-40to55°C
(-40to131°F).
(3) Refer to Table 7 for ground level thermal capabilities. To ensure that the unit can dissipate heat
atanaltitudeofmorethan15000ftandlessthan55000ft,aminimumof2SCFMisrequired.