95-3 Wireless room thermostats, wired valves, wireless
TPI boiler control
95-1 Wireless room thermostats, wired valves, wired TPI
boiler control
95-2 Wireless room thermostats, wired valves, OpenTherm 2
wire boiler control
Y9520Z Sundial RF
²
Pack 5
INSTALLATION INSTRUCTIONS
50047644-006 A
Application
This pack provides a wireless control solution for adding 2 wireless room
thermostats to heating systems, in order to split the heating system
into 2 separate zones and ensure compliance with the latest Building
Regulations.
Pack Contents & Product Descriptions
1 x ST9520C1005 Wireless enabled 7 day programmer with 2
output control relays for switching boilers, pumps
and zone valves in heating systems. It requires
permanent mains 230Vac power.
2 x DTS92E1020 Wireless digital room thermostat with energy
saving ECO function. It operates on 2 x AA alkaline
batteries, giving a battery life of at least 2 years
under typical operating conditions.
2 x table stand for DT92E (optional)
Other Honeywell products, not supplied in this pack, may be required
for a complete installation, depending on the application. For example
BDR91T1004 relay box. See Schematic System Layouts (below) or refer
to www.honeywelluk.com for full details.
Schematic System Layouts
System Operation
DT92E and ST9520C use 2-way communication on an 868MHz radio
frequency (RF) band to control the heating system.
ST9520C operates as the control hub of the system and the DT92E
thermostats are free to be positioned in suitable locations in the 2
separate heating zones.
This functionality is ideal for upgrading existing systems without a room
thermostat to ensure compliance with Building Regulations. It is also ideal
for refurbished systems, where running mains cable from the programmer
to the thermostats and back to the boiler is difficult or impractical.
There are various options for how to connect to the boiler. The simplest
is a direct 230Vac connection. If the boiler supports OpenTherm
communications technology, it is possible to control it using a 2-wire
connection from the ST9520C OpenTherm terminals. If the boiler is
located remotely, it is possible to send the switching signal from the
ST9520C to a remote located BDR91T relay box.
2-way wireless
communication
Honeywell
Sundial RF
²
is a registered
trademark of Honeywell Inc.
OpenTherm®
communication
V4043H
ZONE 1
ZONE 2
V4043H
Radiator(s)
Radiator(s)
DT92E
DT92E
ST9520C
Junction
Box
Junction
Box
Junction
Box
Hot Water
V4043H
ZONE 1
ZONE 2
V4043H
Radiator(s)
Radiator(s)
DT92E
DT92E
ST9520C
Boiler
Hot Water
BDR91T
V4043H
ZONE 1
ZONE 2
V4043H
Radiator(s)
Radiator(s)
DT92E
DT92E
ST9520C
Boiler
Hot Water
OpenTherm®
2-wire connection
This document is to be left with the user
Question and Answer IconNeed help?

Do you have a question about the Honeywell ST9520C and is the answer not in the manual?

Honeywell ST9520C Specifications

General IconGeneral
Programmability7-Day Programmable
Voltage20 to 30 Vac
Frequency50 Hz; 60 Hz
Accuracy±0.5°C
DisplayLCD
ChangeoverManual or Automatic

Summary

Installing the ST9520C Programmer

1.3 Wiring ST9520C

Electrical connection requirements and safety regulations for wiring the programmer.

1.6 Wiring Diagrams

Schematic diagrams illustrating various system wiring configurations for the ST9520C.

Installing the DT92E Room Thermostat

2.3 DT92E Signal Strength Test

Procedure to test RF signal strength, critical for thermostat placement.

Installing the BDR91T Wireless Relay Box

3.3 Wiring BDR91T

Electrical connection requirements and safety precautions for the BDR91T relay box.

System Configuration: ST9520C

4.2 Boiler Service Reminder / Shut-down Feature

Configuration options for service reminders and automatic heating shut-down.

4.3 Installer Setup

Detailed parameters and options for configuring the ST9520C programmer.

4.5 OpenTherm® Setup and Information Display

Configuration for OpenTherm communication and displaying boiler data.

System Configuration: DT92E

5.1 DT92E Installer Mode

Parameters available for customizing the DT92E room thermostat settings.

Binding / Re-binding Procedure

6.1 Binding

Explanation of the process for pairing RF devices in the system.

6.5 How to Bind DT92E to ST9520C

Step-by-step guide for binding the DT92E thermostats to the ST9520C.

Commissioning the System

Related product manuals