10
Deleting a setpoint
fWhen a setpoint is not required, select the
temperature setting
--.-
and confirm with OK.
i
The first setpoint cannot be deleted.
Adding a setpoint
1. Turn the adjustment dial until
add new
is displayed
and confirm with OK.
The temperature display flashes.
2. Use the adjustment dial to select the desired
temperature (Comfort temperature 1, 2 or Setback
temperature) for the new setpoint and confirm
with OK.
The beginning of the new setpoint flashes.
3. Use the adjustment dial to set the desired beginning
for the new setpoint and confirm with OK.
The end of the desired setpoint flashes.
4. Use the adjustment dial to set the desired end of the
new setpoint and confirm with OK.
i
add new is only displayed when less than 6 set-
points are programmed.
Copying the time program
If several HR90 radiator controllers are to operate with
the same time program, the time program only has to be
created at one device (master) and can then be copied
to further radiator controllers.
i
The ACC90 cable is required to copy the time
program.
• 2 x Micro B mini-plugs
• 0.5 m long
• Not included in the scope of delivery
2.
1.
3.
1. Remove the side cover from all the radiator
controllers.
2. Connect the master (with time program) and a further
HR90 radiator controller using the ACC90 cable.
3. Press the buttons AUTO and OK at both devices
simultaneously for 4 seconds.
com mode
is displayed in the display of both devices.
4. Press the PROG button at the master.
master
is displayed on the master and then
trams,mit
.
com mode
is displayed on the other device and then
receive
.
The time program is copied.
5. The copying process is completed when
finished
is
displayed at both devices.
6. After 2 seconds the device with the copied time
program changes to the automatic mode,
com mode
is displayed again at the master.
7. Disconnect the ACC90 cable from the device with the
copied time program.
i
If there are no activities at one of the two radiator
controllers for 4 minutes, they change automatically
to automatic mode.
Copying to further devices
1. Insert the ACC90 cable into the next device.
2. Press the buttons AUTO and OK at the next device
simultaneously for 4 seconds.
com mode
is displayed at this device.
com mode
is displayed at the master.
3. Press the PROG button at the master.
The further copying procedure is the same as
described at the first copying process.
Terminating copying
After the last copying process has been completed:
1. Press the AUTO button at the master in order to
change to the automatic mode.
2. Remove the ACC90 cable and put the side cover back
on at all the devices.