EasyManua.ls Logo

Honeywell VERSAFLOW VORTEX 200 - Page 15

Honeywell VERSAFLOW VORTEX 200
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DEVICE DESCRIPTION
2
15
VERSAFLOW VORTEX 200
www.honeywellprocess.com34-VF-25-137 iss.1 GLO July 2019 US
Max. permissible product and ambient temperatures with signal converter in stainless
steel (bright) or connection box in stainless steel (bright) mounted above the flow
sensor
Temperature class T6 T5 T4 T3 T2
T
amb
in °C 60 65 60 65 60 65 40 60 65 40 60 65
Nominal size
DN1525 75 65 100 100 135 135 1 200 170 1 145 1 225 170 1 145 1
DN4050 75 65 100 100 1 135 1 130 1 200 150 1 130 1 235 150 1 130 1
DN65100 75 65 100 100 1 135 1 115 1 195 1 135 1 115 1 195 1 135 1 115 1
DN150...300 75 65 100 100 1 135 1 135 1 200 155 1 135 1 230 155 1 135 1
Table 2-15: Temperature class in °C
1 Permanent service temperature of connecting cable and cable entry min. 80°C
Temperature class T6 T5 T4 T3 T2
T
amb
in °F 140 149 140 149 140 149 104 140 149 104 140 149
Nominal size
DN1525 167 149 212 212 275 275 1 392 338 1 293 1 437 338 1 293 1
DN4050 167 149 212 212 1 275 1 266 1 392 302 1 266 1 455 302 1 266 1
DN65100 167 149 212 212 1 274 1 239 1 383 1 274 1 239 1 383 1 274 1 239 1
DN150...300 167 149 212 212 1 275 1 275 1 392 311 1 275 1 446 311 1 275 1
Table 2-16: Temperature class in °F
1 Permanent service temperature of connecting cable and cable entry min. 176°F