2
DEVICE DESCRIPTION
16
VERSAFLOW VORTEX 200
www.honeywellprocess.com 34-VF-25-137 iss.1 GLO July 2019 US
Max. permissible product and ambient temperatures with signal converter in stainless
steel (bright) or connection box in stainless steel (bright) mounted at side or
underneath the flow sensor
Temperature class T6 T5 T4 T3 T2
T
amb
in °C 60 65 60 65 60 65 40 60 65 40 60 65
Nominal size
DN15…25 85 65 100 100 135 135 200 200 200 1 240 240 240 1
DN40…50 75 65 100 100 135 135 1 200 200 200 1 240 235 1 225 1
DN65…100 85 65 100 100 135 135 1 200 200 1 200 1 240 240 1 225 1
DN150...300 75 65 100 100 135 135 200 200 200 1 240 240 235 1
Table 2-17: Temperature class in °C
1 Permanent service temperature of connecting cable and cable entry min. 80°C
Temperature class T6 T5 T4 T3 T2
T
amb
in °F 140 149 140 149 140 149 104 140 149 104 140 149
Nominal size
DN15…25 185 149 212 212 275 275 392 392 392 1 464 464 464 1
DN40…50 167 149 212 212 275 275 1 392 392 392 1 464 455 1 437 1
DN65…100 185 149 212 212 275 275 1 392 392 1 392 1 464 464 1 437 1
DN150...300 167 149 212 212 275 275 392 392 392 1 464 464 455 1
Table 2-18: Temperature class in °F
1 Permanent service temperature of connecting cable and cable entry min. 176°F