Voyager XP User Guide 69
Relink Time-Out
Relink Time-Out controls the idle time between relink attempts. An attempt to link 
a scanner to a base or an Access Point typically lasts up to 5 seconds. This is the 
time when the scanner is actually attempting a contact. Relink Time-Out controls 
the amount of time, in seconds, that elapses between the end of one connection 
attempt and the start of the next.
Note: The length of time for an attempt depends on the number of scanners connected to 
a base unit or Access Point. An extra 7 seconds may be required when a connection is 
successful.
Scan the Relink Time-Out barcode, then scan the number of seconds for the set-
ting (from 1-100) from the Programming Chart. Scan Save to save the setting. 
Default = 3 seconds.
Bluetooth/ISM Network Activity Examples
Default values
When the scanner goes out of range, the scanner repeatedly attempts to connect 
to the base unit or Access Point. Each attempt consists of approximately 5 seconds 
of active time followed by 3 seconds of idle time. After one hour, the scanner pow-
ers off and batch mode data is lost.
Maximum Link Attempts set to 15
Other values at default setting
When the scanner goes out of range, 15 attempts are made to link to the base unit 
or Access Point. Each attempt consists of approximately 5 seconds of active time 
followed by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2 minutes, 
the scanner stops trying to connect to the base or Access Point, but retains any 
barcodes that may have been saved in batch mode. After one hour, the scanner 
powers off and batch mode data is lost.
Auto Reconnect Mode set to 0
Maximum Link Attempts set to 15
Other values at default setting
When the scanner goes out of range, no action is taken to relink. When the trigger 
is pulled, 15 attempts are made to link to the base or Access Point. Each attempt 
consists of approximately 5 seconds of active time followed by 3 seconds of idle 
time. After 15 cycles (8*15 =120), or about 2 minutes, the scanner stops trying to 
connect to the base or Access Point, but retains any barcodes that may have been 
saved in batch mode. After one hour, the scanner powers off and batch mode data 
is lost. Refer to Auto Reconnect Mode, to review other events that can start the 
relink process.
Relink Time-Out